Centrifugal pump sourcing and replacement support for municipal water and wastewater, commercial buildings, HVAC, industrial plants, process systems, construction dewatering and irrigation. Send a nameplate photo, model number or application details and we will work up options.
Availability depends on the manufacturer, model and equipment configuration. Model numbers, nameplate photos, part numbers, drawings and equipment photos can help identify the correct components.
Replacement impellers and wear rings matched to the pump model, diameter and material. Cast iron, bronze, stainless steel and special alloys may be available depending on the manufacturer.
Pump shafts and protective shaft sleeves that guard against seal wear and corrosion. Dimensions and material depend on the pump model and seal arrangement.
Ball, roller and sleeve bearings for the pump frame, along with bearing isolators and housing components. Frame size and bearing part numbers help identify the correct replacement.
Single, double and cartridge mechanical seals, plus compression packing and gland components. Shaft size, seal arrangement, fluid and temperature determine the correct selection.
Casing gaskets, cover gaskets and O-rings in standard and specialty elastomer materials. The pump model and flange or cover dimensions identify the correct components.
Elastic, grid and gear couplings that connect the motor to the pump shaft, along with coupling inserts, spiders and key stock. The shaft diameters and coupling model identify the correct replacement.
Casing halves, volute covers, stuffing box covers and related casing components. These are typically identified by the pump model and serial number.
Repair kits that bundle seals, gaskets, bearings and wear components for specific pump models. The pump model and serial number identify the correct kit.
These are common details that can help us prepare a faster and more accurate quote. Requirements vary by product and application, so send whatever information you currently have.
Manufacturer, model number, serial number and pump size. A clear nameplate photo is often enough to start. Include photos of the pump, motor and base if the nameplate is missing or unreadable.
Required flow in GPM, total dynamic head and the operating duty point. If the original design point is unknown, application details and pipe sizes can help estimate it.
Fluid type, temperature, specific gravity, viscosity and solids content. These affect material selection, seal choice and impeller design.
Materials of construction, suction conditions, connection sizes and flange or thread type. Cast iron, bronze fitted, stainless steel or other alloys may be needed depending on the fluid.
Operating speed in RPM, horsepower, voltage, phase and frequency. Include motor nameplate information when available.
Seal arrangement, base dimensions, coupling type and driver information. Photos of the existing installation help confirm fit for direct replacements.
Replacing an existing ITT Goulds 3196 or similar ANSI process pump? Include the existing pump nameplate, mounting dimensions and installation photos so we can evaluate a Barmesa 911S, 911M, 911L or 911LX option. Proper selection depends on pump size, flow, total dynamic head, speed, impeller diameter, materials, seal arrangement, fluid, temperature, motor, mounting and piping configuration.
Ready to source or replace a centrifugal pump? Send your nameplate photo or application details and we will work up options.
Get a QuoteXylem Goulds Water Technology pumps are common in municipal water supply, wastewater treatment and water transfer applications. Goulds Water Technology submersible, booster and end suction pumps handle municipal water and wastewater service. Deming and Berkeley pumps also serve municipal and irrigation applications.
Taco circulators and inline pumps are widely used in hydronic heating and cooling, chilled water loops, hot water recirculation and condenser water service. Weinman and Paco pumps serve commercial building water and HVAC applications including end suction and split case configurations.
Replacing an existing ITT Goulds 3196 or another ANSI process pump? Eagle Pump Supply can review the existing pump information and application requirements to evaluate an appropriate Barmesa 911 Series ANSI process pump option. Barmesa 911S, 911M, 911L and 911LX series serve new and replacement ANSI process applications. Proper selection depends on pump size, required flow, total dynamic head, operating speed, impeller diameter, materials of construction, seal arrangement, fluid properties, temperature, motor requirements, mounting dimensions and existing piping and base configuration. Cornell and Grundfos centrifugal pumps handle industrial process, cooling water, chemical transfer and food and beverage service. Finish Thompson and March magnetic drive pumps handle corrosive and difficult fluids.
Barmesa booster pumps and transfer pumps support dewatering, effluent and pressure boosting applications. AMT and Burks pumps handle transfer, self priming and regenerative turbine service. Crown and Sta Rite pumps serve agricultural and water system applications.
Impellers, wear rings, mechanical seals, packing, shafts, sleeves, bearings and couplings are commonly replaced. Send pump nameplate photos, model numbers, previous quotes, drawings or application details and we will help identify replacement options.